上传

Welcome to Relab

  • Home
  • About Us
  • Products
      • Microscopes & Cameras
        • Biological Microscope
        • Stereo Microscope
        • Fluorescent Microscope
        • Multi-Head Microscope
        • LCD Digital Microscope
        • Digital Eyepiece Camera
        • USB2.0 CMOS Microscope Digital Camera
        • USB3.0 CMOS Microscope Digital Camera
        • Cooled USB3.0 CMOS Microscope Digital Camera
        • WIFI CMOS Digital Camera
        • HDMI Digital Camera
        • HDMI LCD Displayer
      • Microscope Slides & Cover Glass
        • Plain Microscope Slides
        • Frosted Microscope Slides
        • ColorCoat Microscope Slides
        • Adhesion Microscope Slides
        • Blood Smear Microscope Slides
        • Diagnostic Microscope Slides
        • Microscope Slides with Cavity
        • Microscope Cover Glass
      • Centrifuges
        • Mini Centrifuge
        • Low Speed Centrifuge
        • High Speed Centrifuge
      • Centrifuge Tubes
        • Micro-centrifuge Tubes
        • Centrifuge Tube
      • COVID-19 Solutions
        • SARS-CoV-2 Antigen Test Kit
        • Virus Collection and Preservation System
  • News
  • Contact Us
  • Send Inquiry
Member Center
Exit
Data is empty
0
qr Code Url

Scan qrcode to view mobile website

HomeNewsNews
General Instructions for Microscope Maintenance

General Instructions for Microscope Maintenance

2018-09-05
General Instructions for Microscope Maintenance
Maintenance
      
1. Keeping optical elements clean is important to ensure the good optical performance, the microscope should be covered by the dust cover when not working. If there is dust or dirt on the surface, use a blower to remove the dust or use a soft brush to clean the dirt.

2. Clean the objectives should use moist lint-free cloth or cotton swab with cleaning liquid. Don't use excessive liquid to avoid the clarity influence because of liquid penetration.

3. Eyepiece and objective are easily smudged by dust and dirt. When the contrast and clarity decreases or fog comes out on the lens, use the magnifier to check the lens carefully.

4. Low magnification objective has a big group of front lens, use cotton swab or lint-free cloth wrapped around the finger with ethanol and clean gently. 40x and 100x objective should be checked carefully with a magnifier, as the high magnification objective has front lens with a concave of small radius and curvature to achieve high flatness.

Use toothpick with cotton ball or cotton swab for cleaning. Wipe slightly and gently, don't use vigorous force or make scratches, after the cleaning, check the lens surface carefully. If you have to open the viewing tube to check, please be much careful to avoid any touch with the exposed lens near the bottom of the tube, the fingerprint will affect the observation clarity. Refer to the method for eyepiece/objective cleaning for fingerprints.

5. After using 100X objective with oil immersion, please make sure to wipe the lens surface clean. Also check if any oil on 40x objective and wipe it clean in time to make sure the image clear.
       
6. Dust cover is important to make sure the microscope is in good mechanical and physical condition. If the microscope body is stained, use ethanol or suds for cleaning (Don't use organic solvent), DON'T let the liquid leak into the microscope body, which may cause inside electronic components a short circuit or burned.

7. Keep the working condition dry, when the microscope works in high humidity environment for long time, it will increase the chance of mildew. If the microscope must work in such humidity environment, the dehumidifier is suggested.

In addition, if mist or mildew is found on the optical elements, please contact us immediately for professional solutions.

Notice
Follow the below instructions may extend the microscope working life and maintain good working condition:

1. Adjust the light to the darkest before turning off the microscope.

2. When the microscope is power off, cover it with dust cover after the light source is cool about 15mins.

3. When the microscope turns on, you can adjust the light to the darkest if you will not operate it temporarily thus there will be no need to turn on or turn off the microscope repeatedly.

 

Related News

  • image BS-2041T biological microscope application case in hematology department of hospital
    2022-06-29 24
  • image Upgrade traditional microscope to LCD digital microscope solution
    2022-05-13 34
  • image How to clean the microscope
    2022-04-26 31
  • image SARS-CoV-2 Rapid Antigen Test in Pediatric Population
    2022-03-08 22
  • image In the post-COVID-19 era, What should we do at points of entry?
    2022-03-07 19
  • image Is the SARS-CoV-2 Rapid Antigen Detection Test reliable?
    2022-03-07 20
  • image What are the hot products in 2022
    2021-12-01 24
  • image Meet us at the medical and laboratory industries exhibitions
    2019-11-01 25
Sitemap
©2010 - 2022 (306249) All rights reserved
粤ICP备12019139号 粤公网安备44030502001115号
CONTACT
info@relabtechnology.com
+86 18618374633
+86 10 62253705
Company Address:401 Thnology Road ang, Dnguan Chin 52360
E-MAIL
PRODUCTS
  • BRIDGE CRANE
NEWS
  • NEW1
ABOUT
  • OUR ADVANTAGES
Download
  • ARTICLE
CONTACT US
  • PETTER
(306249)